×
模态框(Modal)标题
在这里添加一些文本
Close
Close
Submit
Cancel
Confirm
×
模态框(Modal)标题
×
Toggle navigation
Home
About
About Journal
Editorial Board
Organization
Honor
Subscription
Journal Online
Just Accepted
Current Issue
Archive
Most Read
Most Download
Most Cited
E-mail Alert
Expert
Instruction
Download
Publishing Ethics
Contact Us
中文
Most download
Published in last 1 year
In last 2 years
In last 3 years
All
Please wait a minute...
Please choose a citation manager
RIS (ProCite, Reference Manager)
BibTeX
Content to export
Citation
Citation and abstract
Export
Select all
|
Select
journal1. 2021, 38(4): 296-299.
https://doi.org/10.11726/j.issn.1001-7658.2021.04.017
Abstract
(
736
)
Download PDF
(
2343
)
Knowledge map
Save
Select
journal1. 2019, 36(2): 142-146.
https://doi.org/10.11726/j.issn.1001-7658.2019.02.021
Abstract
(
298
)
Download PDF
(
2189
)
Knowledge map
Save
Select
journal1. 2020, 37(1): 63-67.
https://doi.org/10.11726/j.issn.1001-7658.2020.01.020
Abstract
(
1502
)
Download PDF
(
2153
)
Knowledge map
Save
Select
journal1. 2021, 38(11): 864-867.
https://doi.org/10.11726/j.issn.1001-7658.2021.11.019
Abstract
(
325
)
Download PDF
(
1914
)
Knowledge map
Save
摘要 目的
探讨减压沸腾技术清洗达芬奇手臂的效果。
方法
采用目测法和ATP生物荧光检测法,比较用减压沸腾机和全自动清洗消毒器对达芬奇手臂的清洗效果及其清洗装载所需的时间。
结果
目测法检查合格率A组为98.93%,B组为99.56%,两组器械清洗合格率差异比较无统计学意义(P>0.05)|ATP生物荧光检测法合格率A组为96.89%,B组为97.78%,两组清洗质量合格率比较差异无统计学意义(P>0.05)|装载单根时间A组为(13.2±5) s,B组为(3.3±2)s,装载时间有明显差异。
结论
两种清洗方法均可使达芬奇手臂清洗质量达到标准,但减压沸腾清洗技术可显著提高工作人员的工作效率。
Select
journal1. 2022, 39(7): 555-557.
https://doi.org/10.11726/j.issn.1001-7658.2022.07.023
Abstract
(
436
)
Download PDF
(
1860
)
Knowledge map
Save
Select
journal1. 2019, 36(6): 470-474.
https://doi.org/10.11726/j.issn.1001-7658.2019.06.023
Abstract
(
639
)
Download PDF
(
1704
)
Knowledge map
Save
Select
journal1. 2023, 40(7): 496-497.
https://doi.org/10.11726/j.issn.1001-7658.2023.07.005
Abstract
(
1115
)
Download PDF
(
1657
)
Knowledge map
Save
摘要 目的
观察高锰酸钾消毒片杀菌效果,探讨其对皮肤消毒的价值。
方法
采用悬液定量杀菌试验方法,对高锰酸钾消毒片的杀菌效果进行观察。
结果
该高锰酸钾消毒片有效含量为质量分数92%。在菌悬液内加入小牛血清白蛋白30 g/L条件下,用浓度为3 000 mg/L高锰酸钾水溶液作用1 min,对悬液内白色念珠菌平均杀灭对数值均≥4.0。在菌悬液内加入小牛血清白蛋白3 g/L条件下,用浓度为800 mg/L高锰酸钾水溶液作用2 min,对悬液内白色念珠菌平均杀灭对数值均≥4.0。
结论
高锰酸钾对白色念珠菌具有良好的杀灭效果,但其杀菌效果受有机干扰物影响明显。
Select
CHINESE JOURNAL OF DISINFECTION. 2023, 40(8): 612-616.
https://doi.org/10.11726/j.issn.1001-7658.2023.08.016
Abstract
(
665
)
Download PDF
(
1623
)
HTML
(
490
)
Knowledge map
Save
Select
journal1. 2019, 36(2): 150-153.
https://doi.org/10.11726/j.issn.1001-7658.2019.02.023
Abstract
(
441
)
Download PDF
(
1583
)
Knowledge map
Save
Select
journal1. 2020, 37(2): 137-140.
https://doi.org/10.11726/j.issn.1001-7658.2020.02.019
Abstract
(
474
)
Download PDF
(
1573
)
Knowledge map
Save
Select
journal1. 2019, 36(9): 709-711.
https://doi.org/10.11726/j.issn.1001-7658.2019.09.021
Abstract
(
1005
)
Download PDF
(
1552
)
Knowledge map
Save
Select
journal1. 2021, 38(12): 884-886.
https://doi.org/10.11726/j.issn.1001-7658.2021.12.002
Abstract
(
1005
)
Download PDF
(
1551
)
Knowledge map
Save
摘要 目的
观察一种以苯扎溴铵和六亚甲基四胺为主要杀菌成分的复合季铵盐消毒剂的杀菌效果。
方法
采用悬液定量杀菌试验方法,对该复合季铵盐消毒剂的实验室杀菌效果进行观察。
结果
该消毒剂原液含有苯扎溴铵120 g/L和六亚甲基四胺331 g/L。以该复合季铵盐消毒剂原液体积分数1%浓度,对悬液内大肠埃希菌、金黄色葡萄球菌和铜绿假单胞菌作用0.5 min的杀灭对数值均>5.00,对悬液内白色念珠菌和黑曲霉孢子的杀灭对数值均>4.00。
结论
该复合季铵盐消毒剂对细菌繁殖体和真菌具有快速杀灭效果。
Select
journal1. 2022, 39(5): 397-400.
https://doi.org/10.11726/j.issn.1001-7658.2022.05.023
Abstract
(
525
)
Download PDF
(
1528
)
Knowledge map
Save
摘要 目的
调查基层某重症监护病房(ICU)一起耐碳青霉烯类黏质沙雷菌(CRSM)疑似医院感染暴发事件。
方法
对某ICU发生的3例CRSM感染患者的环境进行采样以及ICU全部工作人员进行粪便筛查,同时采取综合控制措施并评价其效果。
结果
患者A和C为医院获得性感染,患者B无充足的证据表明为医院获得性感染。采取综合控制措施后,连续追踪3个月,未再发生同类感染病例,可以排除医院感染暴发|但是3例患者病原菌的药敏结果几乎完全一致,时间、空间存在相关性,说明病原体在医院内已经发生传播。
结论
基层医疗机构是医院感染管理的薄弱环节,应加强相关部门的技术支持和行政支持,促进医院感染管理工作。
Select
journal1. 2019, 36(1): 60-63.
https://doi.org/10.11726/j.issn.1001-7658.2019.01.022
Abstract
(
333
)
Download PDF
(
1508
)
Knowledge map
Save
Select
journal1. 2023, 40(6): 453-456.
https://doi.org/10.11726/j.issn.1001-7658.2023.06.015
Abstract
(
400
)
Download PDF
(
1500
)
Knowledge map
Save
Select
journal1. 2018, 35(11): 801-804.
https://doi.org/10.11726/j.issn.1001-7658.2018.11.001
Abstract
(
461
)
Download PDF
(
1482
)
Knowledge map
Save
摘要 目的
建立测定消毒剂最小抑菌浓度(MIC)的微量稀释法。
方法
采用微量稀释法,对部分消毒剂的MIC进行测定,并观察部分因素对测定结果的影响。
结果
经对8株肺炎克雷伯菌临床分离株测试结果显示,三氯生有4株菌MIC值孵育48 h比24 h升高2倍,苯扎氯铵有1株菌MIC值升高2倍。继续对102株菌观察,西吡氯铵和醋酸氯己定也有MIC升高2倍的情况,只有十六烷基三甲基溴化铵MIC不发生变化。醋酸氯己定MIC基本不受所用肉汤培养基的影响,阳离子调节MH肉汤测定其余4种消毒剂MIC值为普通营养肉汤的2~4倍。利用OD600对无药物析出的醋酸氯己定和有药物析出的苯扎氯铵MIC进行判定和肉眼判读的结果完全一致。
结论
初步建立了以OD600来判定消毒剂MIC值的96孔板微量肉汤稀释方法。
Select
journal1. 2022, 39(7): 518-521.
https://doi.org/10.11726/j.issn.1001-7658.2022.07.012
Abstract
(
569
)
Download PDF
(
1465
)
Knowledge map
Save
摘要 目的
研究PDCA循环对重症医学科(ICU)医务人员手卫生依从性的影响。
方法
将PDCA循环管理方法应用到手卫生中,研究干预前后ICU医务人员手卫生依从率、正确率及手卫生相关监测指标变化情况。
结果
PDCA循环管理实施后,手消毒剂及洗手液每床日用量较前明显提高,手卫生依从率从64.8%提高到87.4%,正确率从68.9%提高到91.0%,差异均有统计学意义(P<0.001)。在不同的职业中,医师、护士及护理员手卫生依从率在PDCA实施后均明显上升(P<0.05),医师、护士手卫生正确率在PDCA实施后均明显上升(P<0.05)。手卫生“五时刻”的手卫生依从率均有提高(P<0.05),其中“接触患者后”及“接触患者周围环境后”的手卫生依从率较前提高最为显著。
结论
将PDCA循环管理方法应用于手卫生管理中,可有效提高ICU医务人员手卫生依从率和正确率,应不断提高ICU医务人员手卫生依从性情况,并始终贯彻执行。
Select
journal1. 2020, 37(2): 148-152.
https://doi.org/10.11726/j.issn.1001-7658.2020.02.022
Abstract
(
251
)
Download PDF
(
1403
)
Knowledge map
Save
Select
journal1. 2021, 38(1): 63-66.
https://doi.org/10.11726/j.issn.1001-7658.2021.01.019
Abstract
(
152
)
Download PDF
(
1395
)
Knowledge map
Save
Select
journal1. 2019, 36(12): 949-952.
https://doi.org/10.11726/j.issn.1001-7658.2019.12.023
Abstract
(
376
)
Download PDF
(
1385
)
Knowledge map
Save
Select
journal1. 2020, 37(2): 145-147.
https://doi.org/10.11726/j.issn.1001-7658.2020.02.021
Abstract
(
211
)
Download PDF
(
1372
)
Knowledge map
Save
Select
journal1. 2021, 38(9): 705-708.
https://doi.org/10.11726/j.issn.1001-7658.2021.09.019
Abstract
(
463
)
Download PDF
(
1370
)
Knowledge map
Save
Select
journal1. 2023, 40(7): 542-545.
https://doi.org/10.11726/j.issn.1001-7658.2023.07.018
Abstract
(
283
)
Download PDF
(
1353
)
Knowledge map
Save
Select
journal1. 2021, 38(12): 890-891.
https://doi.org/10.11726/j.issn.1001-7658.2021.12.004
Abstract
(
556
)
Download PDF
(
1294
)
Knowledge map
Save
摘要 目的
观察2种84消毒液稳定性及杀菌性能。
方法
采用悬液定量杀菌试验和理化分析方法,对2种84消毒液的稳定性和消毒相关性能进行比较观察。
结果
Ⅰ型和Ⅱ型84消毒液有效氯含量均为57.86 g/L。2种84消毒液密封包装在25℃存放6个月,Ⅰ型和Ⅱ型84消毒液有效氯下降率分别为22.04%和3.01%。有效氯含量均为100 mg/L的Ⅰ型和Ⅱ型84消毒液对悬液内金黄色葡萄球菌分别作用1 min和15 mim,平均杀灭对数值>5.0。Ⅰ型和Ⅱ型84消毒液有效氯含量均为2 500 mg/L,对悬液内枯草杆菌黑色变种芽孢,Ⅰ型84消毒液作用15 min以及Ⅱ型84消毒液作用60 min,平均杀灭对数值>5.0。
结论
Ⅰ型84消毒液稳定性低于Ⅱ型84消毒液,但其杀菌效果明显优于Ⅱ型84消毒液。
Select
journal1. 2018, 35(5): 376-379.
https://doi.org/10.11726/j.issn.1001-7658.2018.05.018
Abstract
(
990
)
Download PDF
(
1282
)
Knowledge map
Save
Select
journal1. 2022, 39(3): 165-168.
https://doi.org/10.11726/j.issn.1001-7658.2022.03.002
Abstract
(
429
)
Download PDF
(
1268
)
Knowledge map
Save
摘要 目的
研究优化过硫酸氢钾复合物粉溶液稳定性的pH值和NaCl含量。
方法
基于同1份样品,将其配制成浓度为1∶〖KG-*3〗100的水溶液,通过调节溶液的pH值和NaCl含量,以溶液中有效氯含量降解至10.0%所用时间作为稳定性考察指标,筛选出稳定性时间最长情况下的pH值和NaCl含量。
结果
当pH值为2.1和2.2时,溶液稳定性随NaCl含量的升高(0.5%~4.0%)而变好,NaCl含量为4.0%时稳定性最好|当pH值为2.3时,NaCl含量为3.0%的溶液稳定性最好|当pH值为2.4~2.8时,NaCl含量为2.0%时均表现出最佳的溶液稳定性。其中,NaCl含量在1.5%~3.0%,pH值在2.5~2.8时,溶液稳定性均较好。
结论
pH值和NaCl含量对过硫酸氢钾复合物粉溶液稳定性时间影响显著,当溶液的pH值为2.5,NaCl含量为2.0%时,溶液稳定性最佳,达到了31 d。
Select
journal1. 2020, 37(11): 818-820.
https://doi.org/10.11726/j.issn.1001-7658.2020.11.006
Abstract
(
258
)
Download PDF
(
1268
)
Knowledge map
Save
摘要 目的
观察一种等离子空气消毒机对车辆和学生宿舍空气和物体表面消毒效果。
方法
采用空气微生物采样器和棉拭涂抹法,对低温等离子体消毒机消毒大巴车、小卧车和学生宿舍空气和物体表面的效果进行检测与评价。
结果
该空气消毒机开机运行60 min,大巴车内空气和表面自然菌消亡率分别为90.63%和69.95%|运行30 min,小卧车内空气中自然菌平均消亡率为96.57%|运行60 min,小卧车和学生宿舍内空气中自然菌平均消亡率分别为95.33%和91.07%,物体表面自然菌消亡率分别为75.68%和64.95%。
结论
该等离子体空气消毒机对车辆内和室内空气消毒效果较好,但对物体表面消毒效果不达标。
Select
journal1. 2023, 40(2): 150-154.
https://doi.org/10.11726/j.issn.1001-7658.2023.02.022
Abstract
(
261
)
Download PDF
(
1233
)
Knowledge map
Save
Select
journal1. 2021, 38(3): 218-221.
https://doi.org/10.11726/j.issn.1001-7658.2021.03.019
Abstract
(
157
)
Download PDF
(
1228
)
Knowledge map
Save
Select
journal1. 2022, 39(8): 625-628.
https://doi.org/10.11726/j.issn.1001-7658.2022.08.021
Abstract
(
216
)
Download PDF
(
1183
)
Knowledge map
Save
Select
journal1. 2021, 38(7): 494-496.
https://doi.org/10.11726/j.issn.1001-7658.2021.07.005
Abstract
(
327
)
Download PDF
(
1173
)
Knowledge map
Save
〖HT5"H〗摘要〓目的〓了解医院使用中的空气消毒机产品性能和实际消毒效果,为空气消毒机的选择提供依据。
方法
〓采用资料调查和现场监测方法,对某医院使用中的各类型空气消毒机使用状况进行调查。
结果
〓对该院8个厂家的空气消毒机的主要结构、工作原理、技术参数、使用方法、注意事项、维护保养等进行了比较。以物理消毒法为主要杀菌因子,由多种消毒净化技术优化组合而成|杀菌元件有效寿命长短不同。不同产品在不同场地动态和静态条件下消毒净化效果表明,实际消毒效果不尽相同,各消毒机之间存在差异,但运行最长时间即静态下运行2 h,对沉降菌和浮游菌消除率均未达到90%。
结论
〓该医院使用的空气消毒机涉及种类多、结构和原理不尽相同,但实际除菌和除尘效果不够理想。
Select
journal1. 2020, 37(1): 59-62.
https://doi.org/10.11726/j.issn.1001-7658.2020.01.019
Abstract
(
2107
)
Download PDF
(
1171
)
Knowledge map
Save
Select
journal1. 2019, 36(8): 626-630.
https://doi.org/10.11726/j.issn.1001-7658.2019.08.020
Abstract
(
195
)
Download PDF
(
1166
)
Knowledge map
Save
Select
journal1. 2022, 39(4): 306-309.
https://doi.org/10.11726/j.issn.1001-7658.2022.04.019
Abstract
(
284
)
Download PDF
(
1145
)
Knowledge map
Save
Select
journal1. 2019, 36(2): 147-150.
https://doi.org/10.11726/j.issn.1001-7658.2019.02.022
Abstract
(
292
)
Download PDF
(
1137
)
Knowledge map
Save
Select
journal1. 2019, 36(10): 796-798.
https://doi.org/10.11726/j.issn.1001-7658.2019.10.024
Abstract
(
238
)
Download PDF
(
1133
)
Knowledge map
Save
〖HT5”H〗摘要 目的 调查分析骨科Ⅰ类手术切口感染的原因,采取适当措施降低手术部位感染率。
方法
分两阶段对百级层流手术间内骨科Ⅰ类手术进行监测,2018年1月1日-6月30日主要搜集干预前手术切口感染的相关因素;2018年7月1日-9月30日对手术切口感染相关的主要因素进行干预。比较干预前后两阶段手术切口的感染率。
结果
干预前阶段手术切口感染率为2.34%,干预阶段手术部位感染率为0,二者差异有显著统计学意义(χ2=3.87,P=0.049)。
结论
加强层流手术室的管理、保证物品及手术器械的消毒灭菌质量、重视术前外科手消毒、严格无菌操作、围手术期抗菌药物的正确应用及医护人员感染控制意识提高等干预措施,可有效降低手术切口感染。
Select
journal1. 2019, 36(10): 721-723.
https://doi.org/10.11726/j.issn.1001-7658.2019.10.001
Abstract
(
327
)
Download PDF
(
1105
)
Knowledge map
Save
摘要 目的
研究电解式臭氧水杀菌效果及其氧化还原电位(ORP)值的影响因素。
方法
采用载体定量杀菌试验和仪器测定法,对一种电解式臭氧水杀菌效果及其ORP值的影响因素进行观察。
结果
本研究电解臭氧水浓度为0.08 mg/L~1.47 mg/L,水的流量190~3 000 ml/min范围内电解式臭氧水的ORP值变化不明显;进水水温在14 ℃~30 ℃范围,随着水温升高ORP值的衰减时间递减。该臭氧水的ORP值在500 mV和600 mV作用1 min,对载体上大肠杆菌杀灭率分别为18.98%和99.72%;ORP值≥700 mV对载体上大肠杆菌作用1 min,杀菌率达到100%。
结论
电解臭氧水ORP值受水温影响明显,保持ORP值≥700 mV时即可保证臭氧水稳定的杀菌效果。
Select
journal1. 2023, 40(2): 98-102.
https://doi.org/10.11726/j.issn.1001-7658.2023.02.006
Abstract
(
359
)
Download PDF
(
1077
)
Knowledge map
Save
摘要 目的
探究五倍子、黄芩、金银花、板蓝根、连翘、薄荷、山楂七味中药及其组方的抑菌作用。
方法
使用水煎煮法提取各单味中药及其组方的活性成分;采用琼脂平板打孔法、纸片扩散法和平板培养法测定其抑菌圈直径、最小抑菌浓度(MIC)和最小杀菌浓度(MBC);设计7因素2水平的正交试验,初步确定最优抑菌配比。选择对抑菌活性影响最小的脱色方法。
结果
7味中药中五倍子对金黄色葡萄球菌的抑菌作用最强,抑菌圈直径(30.3±0.81) mm;山楂对大肠埃希菌的抑菌作用最强,抑菌圈直径(17.7±1.03) mm;黄芩对白色念珠菌的抑菌作用最强,其抑菌圈直径为(14.5±1.38) mm。正交试验结果表明,连翘、山楂、板蓝根、五倍子、金银花、黄芩、薄荷按质量比为2∶〖KG-*2/3〗1∶〖KG-*2/3〗2∶〖KG-*2/3〗2∶〖KG-*2/3〗1∶〖KG-*2/3〗2∶〖KG-*2/3〗1组成的中药组合物抑菌效果最好。75%水提醇沉法脱色对抑菌作用影响小。
结论
五倍子、山楂和黄芩分别对金黄色葡萄球菌、大肠埃希菌、白色念珠菌的抑菌作用最强,7味中药的配伍可以产生协同增效的效果,可使用75%水提醇沉法对药液脱色。
Select
journal1. 2021, 38(10): 781-784.
https://doi.org/10.11726/j.issn.1001-7658.2021.10.018
Abstract
(
153
)
Download PDF
(
1050
)
Knowledge map
Save
〖HT5”H〗摘要 目的 分析科室联系制度联合质量追溯信息系统用于消毒供应中心(CSSD)护理管理的意义。
方法
于2019年8月—2019年10月在笔者所在医院使用科室联系制度联合质量追溯信息系统优化CSSD护理管理。此前CSSD行常规管理。于此前和此后各随机抽取580批次灭菌器械进行观察,对比实施前后医疗器械管理质量、供给器械差错事件发生率、临床科室对CSSD服务质量的满意度。
结果
实施前回收合格率、清洗合格率、包装合格率和灭菌合格率分别为91.90%、93.28%、92.41%和100.00%,实施后分别为99.31%、99.14%、99.66%和100.00%。实施后供给器械差错事件发生率(0.34%)较实施前(3.97%)低。实施后临床科室评估CSSD服务质量满意总分值显著提高。
结论
科室联系制度联合质量追溯信息系统用于CSSD护理管理中,能有效提高器械处理质量,减少供给差错,提高临床科室满意度。
Select
journal1. 2021, 38(6): 410-413.
https://doi.org/10.11726/j.issn.1001-7658.2021.06.004
Abstract
(
295
)
Download PDF
(
1050
)
Knowledge map
Save
摘要 目的
研究气体二氧化氯制备技术及其在消毒中的应用。
方法
通过化学反应方式制备二氧化氯气体和气体熏蒸载体方法,对二氧化氯气体制备技术及其杀菌效果进行评价。
结果
亚氯酸钠、硫酸氢钠和抗坏血酸钠以科学配比混合发生二氧化氯气体。在常温条件下于生物安全柜内,用浓度为6 000 mg/m3的气体二氧化氯,作用30 min可完全杀灭载体上枯草杆菌黑色变种芽孢。
结论
本研究确定了气体二氧化氯发生的新配比,气体熏蒸可有效杀灭载体上枯草杆菌黑色变种芽孢。